ULTRAPROBE® - 2000

 

Specifications

  • Pressure & Vacuum Leak Detection
  • Hydraulic Valve Bypass
  • Exhaust System Leaks
  • Heat Exchangers, Boilers, Condensers
  • Valve & Steam Trap Inspection
  • Bearing Testing
  • Gear/Gear Box Inspection
  • Cockpit Window/ Hatch Leaks
  • General Mechanical Inspection
  • Tanks, Pipes, Leak Testing, etc.
  • Electrical Inspection

Construction:

  • Hand-held metered pistol type made with aluminum and ABS plastic.

Circuitry:

  • Solid State heterodyne receiver with temperature compensation.

Frequency Response:

  • Detect ultrasonic frequencies between 20 kHz and 100 kHz, continuously variable. Frequencies are converted to 50 kHz to 3 kHz audio.

Probes:

  • Scanning Module patented Trisonic plug-in type consisting of a phased array of multiple transducers for airborne ultrasound. This probe is shielded against RF interference.
  • Rubber Focusing Probe (flexible) slips over scanning module to concentrate conical directivity and to shield reception of stray ultrasound. Also fits over Stethoscope Module to shield against high ambient ultrasound while unit is at maximum sensitivity.
  • Stethoscope Module – plug-in type, insulated probe with RF shielding; 4 1/2” (11.4 cm) long stainless steel probe tip, conically shaped for uniform surface contact. Stethoscope Extension Kit: 3-piece, segmented metal rods to increase stethoscope contact range for 20” (50.8 cm) and 31” (766.2 cm).

Transmitter:

Patented warble tone transmission.

Headset:

  • Noise isolating type: Double headset wired monophonic. Impedance16 ohms. Over 23 dB of noise attenuation. Meets or exceeds ANSI specifications and OSHA standards. For hard hat use.

Indicators:

  • Ballistic output meter; linear calibration scale of 0-100 for logging relative measurements. Meter is accurate 1% throughout entire scale. Low Level Battery LED indicator for main housing internal power supply.

Battery:

  • Self contained NiMH rechargeable.

Recharging System:

  • Standard 110V. Also available in 220V.

Features:

  • Frequency Tuning Adjustment Dial: 20-100 kHz with "fixed band" position for ultra-narrow frequency response.
  • Bi-Modal Meter Switch for logarithmic and linear meter scale adjustments.
  • Optional Auxiliary Mode selection for chart recorder output: 0-50 mV.
  • Sensitivity Control – Precision 10-turn adjustment dial with numerically calibrated sensitivity increments for finite gain adjustment.
  • Spring loaded trigger switch.

Overall Size:

  • Complete kit in Zero Halliburton aluminum carrying case: 18.5” x 14.5” x 6.5” (47 x 37 x 17 cm)
  • Pistol unit: 2 lbs. (.9 kg)
  • Complete carrying case: 14 lbs. (6.4 kg).

Sensitivity:

  • Detects .005" (.127 mm) diameter leak @ 5 psi (.34 bar) at a distance of 50 ft. (15.24 m)
  • Threshold*: 1 x 10 –2 std. cc/sec to 1 x 10 –3 std. cc/sec.

Warranty:

  • 1-year parts/labor standard
  • 5 years with completed warranty registration card.

Display Modes:

  • Real Time and Snap Shot.

*depends on leak configuration
**specify Ex rating if needed at time of order.

Ultraprobe 2000 Kit: Meets and exceeds ASTM E1002 2005 requirements for Leak Detection.

Government Codes:

NSN: 6635-01-156-3927, FSCM (CAGE) Code: 59202 Table of allowance #s: 788, 404, 576, 583, 607

Covered by one or more of the following patents:

0151115; 0303776; 0315199; 1206586; 1297576; 1881263; 2562758; 2689339; 4416145; 4823600; 5955670; 6122966; 6339961; 6341518; 6415645; 6655214; 6707762; 6804992

UE Systems is committed to continual product improvement; therefore specifications are subject to change without notice. Warranty details are available by request.

For more information or a quotation contact us.

ULTRAPROBE® 2000
TECHNICAL DATA
Specifications